← Back to blog
5 min read

Can AI drawing review check drawings against Australian Standards as well as the NCC?

AI drawing review can check the NCC clause by clause and every Australian Standard requirement your spec, reports or PPR have written down. Checking the full text of a standard depends on which standards and editions the tool is reading.

TL;DR: Partly. AI drawing review can check drawings against the NCC clause by clause, and it can check any Australian Standard requirement that your specification, consultant reports or PPR have written down, with the clause and the sheet cited. Checking against the full text of a standard depends on whether the tool is reading that standard, and which edition, so ask. Your certifier and consultants still sign off.

Where the question comes from

The spec says "wet area waterproofing to AS 3740". That's 6 words, and a whole standard comes with them.

Nobody on a tender team has time to open it. So the question is fair - if the AI can check the NCC, can it check the standards too?

How do Australian Standards end up on a job?

3 ways.

  1. The NCC calls them up. The deemed-to-satisfy provisions reference standards by number, and Schedule 2 of NCC Volume One lists each one with its edition. Part D4 calls up AS 1428.1 for access. The wet area provisions in Part F2 call up AS 3740.
  2. The specification calls them up, trade by trade.
  3. Consultant reports call them up - the fire engineer, the acoustic consultant, the access consultant.

You also get hold of them differently. The NCC is free to read online at ncc.abcb.gov.au. Australian Standards are copyright documents published by Standards Australia and sold under licence.

So "we've loaded the NCC" and "we've loaded the standards" are 2 separate claims. Ask about each one.

What can AI drawing review check?

There are 3 kinds of check here and they're different jobs.

Is the standard carried through the set? The spec says one thing, the schedule says nothing, and the report says a third thing. A synthetic example - the spec calls for fire doorsets to AS 1905.1, and the door schedule lists 14 doors in fire-rated walls with the FRL column blank. That's one document checked against another and AI does it well, across every sheet, with both sides cited.

Does the drawing meet a requirement someone has written down? When a report or the PPR states the number, the check is that number against the drawings. Another synthetic one - the access report asks for an 850 mm clear opening at accessible doors and cites AS 1428.1, and the schedule shows the accessible toilet door with an 820 leaf. That comes back as a finding against the report clause and the schedule line.

Does the drawing meet the standard's own text? This only works if the tool is reading the standard itself. Ask which standards, which editions and under what licence. If the answer is vague, treat any finding as a prompt to open the clause yourself.

Why does the edition matter?

The NCC references a specific edition of each standard, and it isn't always the newest one on sale. NCC 2022 lists AS 1428.1 as the 2009 edition, and there's a 2021 edition out as well.

A check against the wrong edition gives you a confident wrong answer.

So the tool should name the edition next to the clause, the same way it should name the NCC edition your job was approved under.

What can't be checked from the drawings?

A lot of what a standard asks for is about how the thing gets built, tested and certified. Membrane cure times. The compliance tag on a fire door. Commissioning results.

Those get settled in the ITP and the site inspections, and no drawing shows them.

And a performance solution changes the check. If the fire engineer has written one for an item, the drawings get checked against the fire engineering report for that item. We wrote up how to do that here.

How CIM Build handles it

BCA assessment reads the architectural set against the NCC provisions that apply to the building's class and construction type, and cites the clause, the sheet and the revision behind every finding. The BCA/NCC volumes from 2019 to 2025 and the Red Book are preloaded.

Report compliance reads each consultant report against the drawings and the specification, and PPR vs drawings does the same for the brief. So a standard's requirement that a consultant has written into a report gets checked against the set, cited to the clause and the sheet.

And if your team has a standard detail it insists on, lessons learnt lets you write it as a check in plain English and it runs on every new set from the next revision on.

Each finding gets triaged as reviewed, needs action or RFI, and nothing goes to a consultant until a person sends it.

If there's a particular standard you're worried about on a job, book a briefing and bring that set.

Frequently asked questions

Does the NCC include the Australian Standards? It references them. The text of each standard is a separate document from Standards Australia, and Schedule 2 of the NCC lists the edition that applies.

Can ChatGPT check a drawing against an Australian Standard? It can read the files you upload to one conversation and it's useful for questions about a single document. If it quotes a clause from a standard, check the wording and the edition against your own copy before you rely on it.

Who signs off compliance with a standard? The certifier, and the consultants responsible for that part of the design. AI drawing review gets the list of things to look at in front of them earlier, with the source cited on every line.


Published by CIM.BUILD. This is the text of https://www.cim.build/au/blog/ai-drawing-review-australian-standards without the site design. Index of all pages. Contact.